Montage

When used as an extractor unit, the hood must be fitted with a

120mm diameter hose.

If the outlet hose is installed In a horizontal position, it must

nevertheless be slanted at an angle of 10° so that the air can flow

outside without impediment.

If the cooking vapour Is passed through an outside wall, you will

need a telescopic wall pipe No. E 610 899 004 (120 mm o) from

our range of special accessories.

When installing the hood, make sure you respect the follow­

ing minimum distance from the top edge of the cooking hob/
ring surfaces:

electric cookers

gas cookers

coal and oil cookers

650 mm

650 mm

700 mm min.

The hood cannot be connected to flues of other appliances
that run on energy sources other than electricity.

It is advisable to apply for authorization from the relevant
controlling authority when connecting the outlet to an un­

used chimney flue or combustion gas duct.

The air outlet installation must comply with the regulations

laid down by the relevant authorities.

When the unit is used in its extractor version, a sufficiently

large ventilation hole must be provided, with dimensions that

are approximately the same as the outlet hole.

National and regional building regulations impose a number

of restrictions on using hoods and fuel-burning appliances
connected to a chimney, such as coal or oil room-heaters and
gas fires, in the same room.

The European decree on fuel-burning systems specifies a

maximum depression of 0.04 bar in such rooms.

Hoods can only be used safely with appliances connected to

a chimney if the room and/or flat (alr/environment combina­
tion) is ventilated from outside using a suitable ventilation

hole approximately 500-600 cm^ large to avoid the possibility

of a depression being created during operation of the hood.

If you have any doubts, contact the relevant controlling

authority or building inspector’s office.

Safety
warning for
kitchen unit

installer

27

Advertising