Since the rule for rooms with fuel burning appliances is

“outlet hole of the same size as the ventilation hole”, a hole

of 500-600 cm^, which is to say a larger hole, could reduce the

performance of the extractor hood.

If the hood is used in its filtering function, it will operate

simply and safely in the above conditions without the need

for any of the aforementioned measures.

When the hood is used in its extractor function, the following

rules must be followed to obtain optimal operation:

— short and straight outlet hose
— keep bends in outlet hose to a minimum

— never install the hoses with an acute angle, they must

always follow a gentle curve only

— keep the hose as large as possible (120 mm 0).

Failure to observe these basic rules will drastically reduce

the performance and increase the noise levels of the extrac­
tor hood.