Operating the Control I/O

Inputs

Code

Print

command*

Paper feed
command

Addition print
command *

Subtotal
printing
command

Grand total

printing
command

Delete

command

Cumulative

total delete

command

Input for

disable

printing time

The value is printed on the left side of the paper when

addition printing is done. This value is stored with the
we^ht value and can be retrieved by code as well.
This code is not printed if the value is "00," only

numbers from 01 to 99 can be used.

When this input is negative low (short), the first data

input within 3 seconds is printed.

This command advances the paper one line, negative
low(short).

When this input is negative low(short), the first data

input within 3 seconds is added and printed.

This command prints the subtotal value and clears after

printing.

This command prints the grand total value and does not
clear the subtotal or grand total after printing.

This command deletes the last added data from the

cumulative total value and then prints the message

"^CANCEL". It is unable to perform this command if

there is no cumulative total value.

This command deletes the cumulative total value and
then prints the message "¥CLEAR". It is unable to

perform this command if there is no cumulative total

value.

Time printing is disabled while this input is ON. Once

OFF, the time printing is preformed once more on the

next printing time. In cumulative total printing, time
printing is preformed regardless of the input.

This output is turned ON when the data buffer exceeds

75 lines.

Outputs

Busy

Printing

This output is turned ON when the unit is printing,

announcement Control inputs are not accepted during this time.

Therefore, enter the control input when this output is

OFF.