Disarmed Notification

This feature will notify the user when the vehicle is left disarmed after Ignition is turned off, or

when the Module is disarmed after being previously armed, the opening or closing of a Door

will cause the Horn or the Siren to sound once after 10 sec. to warn the user that the vehicle

was left unprotected. Pressing

lock

or

unlock

will cancel this timer.

Two-Stage Disarm

When the Siren is sounding, pressing

unlock

will stop the siren - but without unlocking or

disarming the vehicle. You can disable this feature by selecting corresponding option in the

Passive or Active Function.

Shock Sense Bypass

When

aux

3

is programmed for Trunk with Disarm/Rearm option, and the Trunk pin from the

vehicle has been connected to the Door Pin input wire (diode isolated), it is not necessary to

press on

unlock

to disarm the Alarm prior to pressing the

trunk

button.

When the Trunk is opened by remote control, the Door ZonerTrunk pin” will be ignored; the

Shock Sensor will also be ignored until the Door Zone/”Trunk pin" closes. Monitoring will

resume 5 seconds after the Door Zone (Trunk pin) is closed.

Resetting The Module

The system is equipped with a reset function that allows the installer to erase all Transmitter

codes and return all programmed Options to the factory default values.

To reset the Module:

1.

FLASH the Hood pin switch.

2.

Before the 20 seconds have passed, Press the Valet Button 6 times or more, until

the Parking Lights start to flash.

3.

The Parking Lights will flash 8 times confirming the Reset.

Table 12

Events Logging

The Module will play back the last 4 Start Failure Events Codes and the last Intrusion Code

via the Parking Lights and L.E.D.

Events playback

Ensure that the Hood is up and that the Ignition is

off

.

Hold down the Hood Pin-switch for 4 seconds.

Release the Pin-switch.

The Parking Lights will come on.

With the Parking Lights on, immediately push the Pin-switch 3 times.

The Parking Lights and L.E.D. will flash the five events stored In memory.

The first four playback codes are Start Failure Events, while the last playback code is an

Intrusion Code. There is a pause after each event code is played back.

The system will play back the most recent event first, then the second most-recent, and so

on. If there are no events at all to report, the Parking Lights will give one long flash.

Start Failure Codes via Parking

4

^ "

Brakes

5 X = No Tach cut-off

6 X = Hood

Lights

1 X = No Start

3 X = Hardware Reset

7

X = Engine Running, no Ignition

detected, or Tach before Start

P.18

Installation Guide AS-6205Ì SH

Introduction

This Guide contains all information pertinent to the installation. Most (if not all) features are

grouped in the User Guide and therefore, should you need information on a feature, you

should refer to the User Guide

Included in the Package

Please review the Installation Guide before beginning the installation, particularly the Wiring

Schematic and the Programming Options.

It is very important that you familiarize yourself with the programming and the operation of the

system, even if you have already installed a similar system in the past. There are many great

features that may be overlooked if the manual is not read; this would prevent you from

maximizing the potential of the Module.

Prior to the installation, make sure that all the hardware components required to install the

system are in the box.

The following Is a list of components Included In the kit:

1 - Control Unit

1 -

five-pin 18 AWG Harness (Main

1 - Super-regeneration monopole

Harness)

receiver or Long-range super-

1-

twelve-pin 22 AWG Harness

heterodyne receiver

(Accessories Harness)

2 - Multi-channel 5-button

1 -

two-pin 22

a

W

g

Harness

Transmitters

(Accessories Harness)

1 - Plug-in dual-zone Shock Sensor

1 -

five-pin Harness (Data Port Harness)

1 - Plug-in Push-button Valet Switch

1 -

Parts bag: a Hood Pin-switch, a

1 - High-power 120-dB 6-tone Siren

connector, wires and a warning label

1 - six-pin 14 AWG Harness

1 -

User Guide.

(Ignition Harness)

INDUSTRY CANADA USER NOTICE (Canada):

Operation is subject to the following two conditions: (1) this device may not cause

interference, and (2) this device must accept any interference, including interference that may

cause undesired operation of the device.

To reduce potential radio interference to other users, the antenna type and its gain should be

so chosen that the equivalent isotropically radiated power (EIRP) is not more than that

required for successful communication".

FCC USER NOTICE (U.S.A.):

The manufacturer is not responsible for any radio or TV interference caused by unauthorized

modifications to this equipment. Such modifications could void the user's authority to operate

the equipment.

AS-6205Ì SH Installation Guide

P.3