12

YELLOW

(+) Glow-

plug Light

Input

This positive input will monitor the Glow Plug Light in Diesel Mode: it will

wait until the Glow Plug Light goes out to crank the Engine. Connect to

the side of the Glow Plug Light that is positive when the Light is on.

Note: In Diesel Mode there is a 18-sec. crank timing delay (or

approximately 25-sec. if the run time is set to 30 min.): if the Glow Plug

Light is still on after the delay expires, the Module will proceed to start

the Engine.

(Also known as the “wait-to-start light”.) The purpose of the Glow-

plug circuit on diesel vehicles is to pre-heat the Combustion

Chamber before the vehicle is started.

When a Remote Starter is installed on a diesel vehicle, the Glow-

plug section of the Ignition circuit must be activated and allowed to

operate before the vehicle is remote-started. For that purpose, the

Glow-plug input wire of the Module must be connected to the

Glow-plug indicator light of the vehicle. The Module will only accept

positive Glow-plug input signals, if the signal is negative, use a

relay to invert its polarity. A diode must be added between the

negative Glow-plug trigger on the relay and the negative Glow-plug

wire of the car. This is to prevent feedback effects on the Glow-

plug indicator light on the instrument cluster: the light on the dash

would come on because of the feedback, even though the circuit is

off.

When the user remote-starts the vehicle:

• The Module will power up the Ignition circuit and wait to engage the

Starter Motor while the Glow-plug indicator light is still on.

• The Module will engage the Starter Motor as soon as the Glow-plug

light (+) goes out.

• Minimum waiting time is 3 seconds.

• Maximum waiting time is 25 seconds (approx.).

If no Glow-plug wire is found on the vehicle, the Glow-plug input on

the Module may be “timed out”. The Module will power up the

Ignition and Glow-plug circuits and simply wait for the time-out

before starting:

Connecting the Glow-plug input wire of the Module to Ignition will

hold the ignition

on

for the maximum waiting time of approximately

25 sec. (recommended).

Keeping the Glow-plug input wire of the Module unconnected will

hold the ignition

on

for the minimum waiting time (3 sec., not

recommended in very cold environments).

Connect the Glow-plug wire to the Ignition wire only after Tach has been

programmed (i.e.: Connecting the Glow-plug wire is one of the very last

steps in the installation process).

OPTION 2*

Ignition Valet - ENABLED

OPTION 3

Ignition Valet - ENABLED

2-Pin Harness

Wire

Description

1

blue

/ WHITE

( -) AUX 2 output

• 500 mA negative output. Can be programmed for one of the following

options:

• Constant while the

lock

and

unlock

buttons are pressed, + 1 sec. after

the buttons are released.

• Pressing the

lock

+

unlock

buttons simultaneously will toggle the

aux

2

Horn Honk / Siren Timing (Optionai)

1. Make sure that Mode 3 Function 4 Optioni or Option 3 is activated.

2. FLASH the Hood Pin Switch

Before the 20 seconds have passed,

3. Press and hold the Brake Pedal.

• Press the

start

and

unlock

buttons simultaneously on the Transmitter.

• The Horn/Siren will sound 5 times.

4. Release the Brake Pedal.

5. To change the timing:

a. To increase the Horn Honk/Siren by 3 ms, press the

lock

button.

b. To increase the Pulse by 10 ms, press the

start

c. To decrease the Pulse by 3 ms, press the

unlock

button.

d. To decrease the Pulse by 10 ms, press the

trunk

button.

6. To save the setting: press

lock

and

unlock

. If 3 Honks/Chirps are heard the new value

has been saved.

For each timing change, the Horn/Siren will sound with the new setting, except

under the following circumstances:

• When the lower limit of 5 ms is reached, the Horn/Siren will sound for 1/4 second.

• When the upper limit of 200 ms is reached, the Horn/Siren will sound for

3/4 second.

A system reset will set the system back to the default: 30 ms

Close the Hood to cancel the changes.

Table 4

Auto Tach Programming Procedure

NOTE:

If no tach has been programmed and the

start

button

is pressed, there will be no start attempt and the

vehicle will give 5 flashes.

If another Tach Programming is required, simply

repeat the Auto Tach Programming Procedures.

The Module stores the Tach setting, being

Auto Tach

or conventional Tach, until the Module is reset.

This process can be carried out instead of the conventional Tach Programming Procedure.

1.

Make sure all the connections are done properly and that the Module has been

powered-up.

2.

With the Hood up (Ground on the Hood Pin line), start the vehicle using the key.

3.

Let the Engine reach proper idle speed

The Parking Light output from the Module is activated when the vehicle starts and it

will shut off once the Tach signal is detected.

4.

Press and hold the Brake Pedal until the Parking Light output from the Module

flashes 5 times.

5.

Turn the Ignition

off

. At this point, the Tach setting has been programmed.