All Doors unlock upon the 2"^ , 4“i, 6“i > pressing of the UNLOCK button.

Mode 2

‘Indicates default setting

Function 1 - Home Valet Mode

OPTION 1

Home Valet enabled

OPTION 2‘ Home Valet disabled
OPTION 3

Home Valet disabled

Function 2 - Safe Start

OPTION 1
OPTION 2*

OPTION 3

Safe Start enabled
Safe Start disabled
Swap Start - increased safety mode:

• To Start: press Lock and Unlock buttons simultaneously.

• Press the START button to activate AUX 2.

Function 3 - Engine Run Time

OPTION 1

Run time - 4 minute in Gas mode / 9 minutes Diesel mode.

OPTION 2*

Run time - 15 minute in Gas mode

/ 20 minutes

Diesel mode.

OPTION 3 Run time - 25 minute in Gas mode / 30 minutes Diesel mode.

Function 4 - Idle/Turbo Mode

OPTION 1

Idle/Turbo Mode disabled

OPTION 2*

Turbo Mode enabled

OPTION 3

Turbo Mode disabled

Function 5 - Engine Type and Cold Weather Mode

OPTION 1

Diesel Engine Mode and 20-minute run time in Cold Weather Mode.

OPTION 2*

Gasoline Engine Mode and 4-mlnute run time In Cold Weather Mode.

OPTION 3 Diesel Engine Mode and 9-minute run time in Cold Weather Mode.

Mode 3

Function 1 - Siren Chirps

OPTION 1
OPTION 2*
OPTION 3

OPTION 4

‘indicates default setting

Warning Chirps only; Lock Confirmation if the Lock button is press 2nd time.
Chirps enabled.
Chirps enabled with Open-Zone notification.

(Siren warning 10 sec. after arming if a door is left open)
(Also used for vehicles with Dome Light Delay).
Chirps disabled and Lock confirmation if the LOCK button is press 2nd time.

Function 2 - Passive Or Active Arming

OPTION 1

Active Arming

OPTION 2*

Passive Arming (30 sec.)

OPTION 3 Passive Arming (30 sec.) / no TWO-STAGE DISARM
OPTION 4 Active Arming with Disarmed Notification.

Function 3 - Ignition Monitoring: Siren Mode / Horn Mode

OPTION 1 Siren Mode: Ignition Monitoring - disabled.
OPTION 2* Siren Mode: Ignition Monitoring - enabled.
OPTION 3

Horn Mode: Ignition Monitoring - disabled.

OPTION 4

Horn Mode: Ignition Monitoring - enabled.

Function 4 - Shock Sense / Warn Away

OPTION 1 Shock Sense - Ignored / Warn Away - ignored
OPTION 2* Shock Sense - monitored / Warn Away - monitored
OPTION 3

Shock Sense - Monitored / Warn Away - ignored

OPTION 4

Shock Sense - Ignored / Warn Away - monitored

Function 5 - Ignition Valet

OPTION 1

Ignition Valet - DISABLED

P.12

Installation Guide

AS-6205Ì SH

output

ON

for a 30-second cycle and shuts off automatically unless the user

presses

lock

and

unlock

before the end of that cycle, at which point, the

AUX2

output shuts off.

• This output can also be used as Priority Door Unlock.

Car Finder is enabled or disabled in the

aux

2

function programming.

2

YELLOW

(-) Parking Light

output

• 500 mA negative Parking Light output

Note: Ensure that the voltage does not vary when the dimmer control

switch is turned up or down. If this is the case, it is not the right wire.

There Is also a positive Parking Light output. Only one of these

two different outputs needs to be connected.

Flashing the Hood Pin

What is Flashing the Hood Pin?

It is a procedure that makes the Module go into the Programming Centre. Once the Module

is in the Programming Centre, the Installer has no more than 20 seconds to get into one of

the sub-menus. Failure to do so will result In the Module exiting the Programming

Centre and the Installer will have to

Flash the Hood Pin

once more.

Remember:

You

can

use

the

Programming

Assistance Button instead of the Hood Pin any time

the Hood is up.

The Installer >

The Module >

1-

Press and hold the Hood pin for 4 seconds.

2-

Let go of the Hood Pin.

Parking Lights “ON”

3-

While the Parking Lights are on, press down the

Hood Pin once more.

4-

Release the Hood Pin again --be careful not to

over flash the Hood Pin as this will bring up the

Events Playback and will not bring you the

Programming Centre.

“ON” for 20 seconds

5-

You have 20 secs to select one of the sub-menus.

Once inside the Programming Centre, the Installer has a selection of many different sub­

menus. Once you are in the Programming Centre, you have the option of the following

menus:

a)

Transmitter Programming >.

p.10

b)

Options Programming.............

p.10

c)

Horn Honk/Siren Timing* (*if available)........... ....... p.13

d)

Tach Programming.................

p.13

Remember: Once the Parking Lights are on Solid,

you have up to 20 seconds to select a sub-menu.

Failure to do so will result in the Module exiting the

Programming Centre and you will have to Flash the

Hood Pin once more.

AS-6205Ì SH

Installation Guide

P.9

Advertising