background image

Installation Instructions /

A

CAUTION

Because the compressor is located on the controls
side of the unit. this side will be heavier and more
awkward to manipulate. Inadequate support on
control side of the unit can result in personal injury
and damage to your unit and property. Therefore,
it is recommended to have someone assist you
during the installation of this unit.

Select the Best Location

A. Your room air conditioner was designed to

fit easily into a single or double hung window.

However, since window designs vary, it may be

necessary to make some modifications for safe

and proper installation.

B. Make sure window and frame is structurally

sound and free from dry and rotted wood.

C. For maximum efficiency, install the air conditioner

on side of the house or building which favors more

shade than sunlight. If the unit is in direct sunlight,

it is advisable to provide an awning over the unit.

D. Provide sufficient clearance around the cabinet

to allow for ample air circulation through the unit.

The rear of the unit should be outdoors and neither

in a garage nor inside of a building. Keep unit as far

away as possible from obstacles and obstructions
and at least 30” above the fioor or ground ^ee right

figure). Curtains and other objects within a room

should be prevented from blocking the air flow.

E. Be certain the proper electrical outlet is within

reach of the installation. Use only a single outlet

circuit rated at 15 amps. All wiring should be In

accordance with local and national electrical codes.

F. Your unit was designed to evaporate condensation

under normal conditions. However, under extreme

humidity conditions, excess condensation may cause

base pan to overflow to the outside.

The unit should be installed where condensation

nm-off cannot drip on pedestrians or neighboring

properties.

Window opening requirements

see table below

AW-05CM1FLU

AW-05CR1FHLU

Cabinet size

(W*H*D)

Min. Window

opening

21"

Max. Window

opening

35"

Min. Window

height

14"

O