Table 7-2 signals: cold reset procedure – ADLINK aTCA-N700 User Manual
Page 38
aTCA-RN720 User's Guide
38
Deactivate
Figure 7-3 Deactivate Procedure
⒮
Shelf manager sends Deactivate to IPMC.
①
IPMC sends Deactivate to LMP via PAYLOAD Interface (UART).
②
LMP completes the operation and sends the completion message via PAYLOAD Interface
(UART) to IPMC.
③
IPMC initiates Power Down sequence to power off Front Blade and RTM.
Table 7-3 Signals: Deactivate Procedure
Signal name
Status
PAYLOAD Interface
P5(4),P5(5)
Deactivate Command
- IPMI Message
Deactivate Done Indicator
- IPMI Message
Activate
Figure 7-4 Activate Procedure
⒮
Shelf manager sends Active Command to IPMC.
①
IPMC initiates Power ON sequence to power ON Front Blade and RTM.
Table 7-4 Signals: Activate Procedure
Signal name
Status
PAYLOAD Interface
P5(4),P5(5)
Activate Command
- IPMI Message
Deactivate Done Indicator
- IPMI Message