Specifications

11

cPCI-6520

Notes:

1. The SATA direct connector is removable (DB-LSATA) and can

be replaced with a CFast socket adapter. A CFast card and
SATA drive cannot be used simultaneously.

2. ADLINK-certified thermal design. The thermal performance is

dependent on the chassis cooling design. Sufficient forced air-
flow is required (see 2.4 "Thermal Requirements"). Tempera-
ture limit of optional mass storage devices may affect the ther-
mal specification.

3. The storage device limits the operational vibration. When appli-

cation requires higher specification for anti-vibration, it is rec-
ommended to use a flash storage device.

Environmental

• Operating Temperature

2

:

Standard: 0 to 60°C with forced air flow
ETT: -20°C to 70°C with forced air flow (cPCI-ET6520)
EX: -40°C to 85°C with forced air flow (Core™ i7-3555LE &
Core™ i7-3517UE only)

• Storage Temperature: -40°C to 85°C
• Humidity: 95% non-condensing
• Shock: 15G peak-to-peak, 11ms duration, non-operating
• Vibration

3

: Operating 2 Grms, 5-500Hz, each axis w/o hard

drive

EMI

• CE EN55022
• FCC Class A

Table 2-1: cPCI-6520 Blade Specifications