Utilities

59

cPCI-6520

7

Utilities

7.1

Watchdog Timer

This section describes the operation of the cPCI-6520’s watchdog
timer (WDT). The primary function of the WDT is to monitor the
cPCI-6520's operation and to reset the system if a software appli-
cation fails to function as programmed. The following WDT func-
tions may be controlled using a software application:

X

enabling and disabling

X

reloading timeout value

The cPCI-6520 custom WDT circuit is implemented using the
internal IO of the Winbond SuperIO W83627UHG which is at 2Eh
of LPC. The basic functions of the WDT include:

X

Starting the timer countdown

X

Enabling or disabling WDT

X

Enabling or disabling WDT countdown LED ON

X

Reloading the timeout value to keep the watchdog from tim-
ing out

X

Setting the range of the timeout period from 1 to 15300 seconds

X

Sending a RESET signal to the system when the watchdog
times out

Using the Watchdog in an Application

The following section describes using the WDT functions in an
application. The WDT reset function is explained in the previous
section. This can be controlled through the registers in the cPCI-
6520's SuperIO.

An application using the reset feature enables the watchdog func-
tion, sets the count-down period, and reloads the timeout value
periodically to keep it from resetting the system. If the timer count-
down value is not reloaded, the watchdog resets the system hard-
ware after its counter reaches zero.

ADLINK provides a demo DOS utility in the ADLINK All-In-One
CD. You can find it in the following directory: X:\cPCI\cPCI-
6520\WDT.