7 utilities, 1 watchdog timer, Setting the watchdog by ipmi command – ADLINK cPCI-3971 User Manual

Page 105: Wdt commands, Chapter 7, utilities: describes the utilitie, Watchdog timer, 7utilities

Advertising
background image

Utilities

91

cPCI-3970

7

Utilities

7.1

Watchdog Timer

This section describes the operation of the cPCI-3970’s watchdog
timer (WDT). The primary function of the WDT is to monitor the
cPCI-3970's operation and to reset the system if a software appli-
cation fails to function as programmed. The following WDT func-
tions may be controlled using a software application:

X

enabling and disabling

X

set and get current configuration

X

reloading timeout value

The cPCI-3970 custom WDT functionality is implemented using an
Intelligent Platform Management Controller (IPMC) and controlled
using Intelligent Platform Management Interface (IPMI) com-
mands.

Setting the Watchdog by IPMI Command

The following section describes how to set the WDT functions
using IPMI commands. For more detailed information about IPMI
commands, please refer to IPMI specification: Intelligent Platform
Management Interface Specification Second Generation v2.0
.

WDT Commands

These commands enable the watchdog function, set the count-
down period, and reload the timeout value periodically to keep it
from resetting the system. If the timer countdown value is not
reloaded, the watchdog resets the system hardware after the
counter reaches zero.

Command

NetFn Code

Cmd Code

Reset Watchdog Timer

App (18h)

22h

Set Watchdog Timer

App (18h)

24h

Get Watchdog Timer

App (18h)

25h

Advertising