Thermal detection, Voltage detection from external sensor – ADLINK cPCI-3971 User Manual
Page 149
IPMI User Guide
135
cPCI-3970
Thermal Detection
This command is used to get temperatures from external sensor
components.
Voltage Detection from External Sensor
This command is used to get voltages from external sensor com-
ponents.
Action
Byte
Value
Description
Request
0
18h
NetFn/LUN
1
59h
Defined command
2
01h~02h
01h : CPU Temperature
02h : System Temperature
Response
0
Complete Code
00h means OK
1:2
Assigned
Temperature value
from Request
It gets digital raw data. The
practical value can be
translated by formula.
Action
Byte
Value
Description
Request
0
18h
NetFn/LUN
1
5Ah
Defined command
2
01h~08h
01 : +1.8V
02 : +1.5V
03 : CORE V
04 : VCC GFX
05 : CPU +1.05V
06 : PCH +1.05V
07 : VCCSA
08 : +0.75V
Response
0
Complete Code
00h means OK
1:2
Assigned Voltage
value from Request
It gets digital raw data. The
practical value can be
translated by formula.