ZTW103 Advanced Instructions, Release 1.1
P/D 102406

HomePro

by ADVANCED CONTROL TECHNOLOGIES, INC.

0728-01

4

level rather then the start level embedded in the command. To change this, simply set the configuration
parameter above to 0.

Adjusting Dim Rate

• Parameter 7-12
• Length: 1 Byte
• Valid Values: (See next)

Note that this only affects a level that is reported or possibly sent by the ZTW103 since the ZTW103
does not control a load.

For example: There are 3 sets of parameters that can adjust the dimming rate of the ZDW120.

1. One set to control how fast the dim rate is when the dimmer receives a Z-Wave command

excluding ALL ON or ALL OFF command.

2. One set to control how fast the dim rate is when the dimmer is locally controlled.
3. One set to control how fast the dim rate is when the dimmer receives an ALL ON or ALL OFF command.

These values can be changed instantly to allow various scenes and effects.
The first of these parameters is the “dim step” (dim rate) parameter. It can be set to a value of 1 to 99. This value
indicates how many levels the dimmer will change when the timer (discussed below) expires.
The second parameter is the timing (how fast the dim rate) parameter. It can be set to a value of 1 to 255.
This value indicates in 10 millisecond resolution, how often the dim level will change. For example, if you set this
parameter to 1, then every 10mS the dim level will change. If you set it to 255, then every 2.55 seconds the dim
level will change.
With the combination of the two parameters that can control the dim rate, the dimmer can be adjusted to dim from
max to min or min to max at various speeds between 10 millisecond and 252.45 seconds (over 4.25 minutes).

On/Off Command dim rate (excluding ALL ON/ALL OFF commands)

• Parameter 7
• Dim step Parameter (default = 3)
• Valid Values: 1-99

• Parameter 8
• Dim timer Parameter (default =10)
• Valid Values: 1-255

Local Control dim rate

• Parameter 9
• Dim step Parameter (default = 3)
• Valid Values: 1-99

• Parameter 10
• Dim timer Parameter (default = 10)
• Valid Values: 1-255

ALL ON/ALL OFF dim rate

• Parameter 11
• Dim step Parameter (default = 3)
• Valid Values: 1-99
• Parameter 12
• Dim timer Parameter (default = 10)
• Valid Values: 1-255

Disable Group 4 During a Dim Command

• Parameter 13
• Length: 1 Byte
• Valid Values = 0 or 1 (default 0)