ZTW103 Advanced Instructions, Release 1.1

P/D 102406

HomePro

by ADVANCED CONTROL TECHNOLOGIES, INC.

0728-01

5

Note that this only affects a level that is reported or possibly sent by the ZTW103 since the ZTW103
does not control a load.

After the ZTW103 is commanded to stop dimming when it has been dimming because of the DIM START
command, it will then command the Z-Wave devices that are in Group 4 to its new level. To prevent the ZTW103
from commanding the Z-Wave devices in Group 4 during this particular occurrence, set Parameter 13 to the
value of 1.

Enable Shade Control Group 1

• Parameter 16
• Length: 1 Byte
• Valid Values = 0 or 1 (default 0)

The ZTW103 can control shade control devices via its group 1 if this configuration parameter is set to 1.

Enable Shade Control Group 2

• Parameter 14
• Length: 1 Byte
• Valid Values: 0 or 1 (default 0)

The ZTW103 can control shade control devices via its group 2 if this configuration parameter is set to 1.

Enable Shade Control Group 3

• Parameter 15
• Length: 1 Byte
• Valid Values: 0 or 1 (default 0)

The ZTW103 can control shade control devices via its group 3 if this configuration parameter is set to 1.

LED Transmission Indication

Parameter 19

Length: 1 Byte

Valid Values = 0 , 1, 2 (default 2)

The ZTW103 will flicker its LED when it is transmitting to any of its 4 groups. This flickering can be set to not
flicker at all (set to 0), to flicker the entire time it is transmitting (set to 1), or to flicker for only 1 second when it
begins transmitting (set to 2). By default, the ZTW103 is set to flicker for only 1 second.

Poll: Minutes

Parameter 20

Length: 1 Byte

Valid Values = 1 through 255 (default: 2)

The ZTW103 will poll the first node in Group 1 in order to keep itself synchronized with the group if this
configuration parameter is set to 1. How often it will poll is configured using the parameter above.

Poll First Node in Group 1

Parameter 21

Length: 1 Byte

Valid Values = 0 , 1 (default 0)

The ZTW103 will poll the first node in Group 1 in order to keep itself synchronized with the group if this
configuration parameter above is set to 1.

Each Configuration Parameter can be set to its default setting by setting the default bit in the Configuration Set
command. See your controller’s instructions on how to do this (and if it supports it).

All Configuration commands will be reset to their default state when the ZTW103 is reset from the Z-Wave system.