Ditch Witch JT1220 User Manual

Page 174

Advertising
background image

JT1220 Mach 1 Operator’s

Manual

Service - 173

Startup/10 Hour

CMW

Check Pipe Auto Lubricator Spray
Nozzle

Check pipe auto lubricator spray nozzle before
startup and every 10 hours of operation. Ensure
that nozzle is free of obstructions and operates
properly. Clean as needed.

To clean

1.

Rotate handle to the upward, or cleanout, position (A).

2.

Operate pump until obstruction is flushed.

3.

Rotate handle to the downward, or spray, position (B).

4.

Clean nozzle guard. If necessary, pull handle/nozzle insert out of housing to clean with fine wire or
solvent.

Check Pipe Auto Lubricator
TJC Level

Check pipe auto lubricator TJC level before
startup and every 10 hours of operation. Change
pail as needed. See “Change Auto Lubricator
TJC Pail” on page 186 for procedure.

NOTICE: Ditch Witch tool joint compound is
specially formulated to work with Ditch Witch
pipe lubrication system. Use of other tool
joint compounds will clog system. See
“Recommended Lubricants/Service Key” on
page 165 for more information.

NOTICE: Ditch Witch tool joint compound is
specially formulated to work with Ditch Witch
pipe lubrication system. Use of other tool
joint compounds will clog system. See
“Recommended Lubricants/Service Key” on
page 165 for more information.

Advertising