Mr90 operator’s manual – Ditch Witch MR90 User Manual

Page 82

Advertising
background image

MR90 Operator’s Manual

Service - 81

10 Hour

CMW

®

Clean Water Pump Filter

Clean water pump filter every 10 hours and
replace as needed.

1.

Open filter housing.

2.

Remove element and rinse housing thoroughly
with water.

3.

Inspect element for signs of collapse and for
brittle or broken rubber seals on the ends of
the element. Replace as needed.

4.

Replace element and close filter housing.

Check Radiator

Check radiator for dirt, grass, and other foreign
matter every 10 hours. Clean out with compressed
air or spray wash if required. Be careful not to
damage fins with high-pressure air or water. Check
more often if operating in dusty or grassy
conditions.

Advertising