Debris tank, Fx25 operator’s manual – Ditch Witch FX25 User Manual
Page 92
Advertising
FX25 Operator’s
Manual
Service - 91
As Needed
CMW
Debris Tank
Clean Primary Shut-off Valve
Clean primary shut-off valve as needed. Replace
primary shut-off valve as needed.
To clean:
1.
Open tank door. See “Drain Tank” on page 51.
2.
Spray valve housing inside vacuum tank with
high-pressure water.
3.
Store water pressure hose.
4.
Close tank door. See “Drain Tank” on
page 51.
To remove:
1.
Loosen three wingnuts (1) and pull out valve housing (2).
2.
Remove ball (3).
3.
Clean ball and housing with high-pressure water.
4.
Replace ball and housing.
5.
Tighten wingnuts.
22
33
11
j32om026h.eps
j32om026h.eps
Advertising