background image

Locate - 30

250R/T Operator’s Manual

Passive Location

CMW

Mark the Line

Sweep, focus, and trace all detected signals in the area. Mark line paths with colored paint or flags. See
the chart below for standard color markings for line locations.

Special Situations

Situation

What to try

Signal is lost.

Walk in a circle to detect a tee or bend in the line.

Signal varies from low to high and is
unstable.

Check the transmitter connection. If connection is good
and signal is still unstable, mark as a hand-dig area.

Receiver does not function properly.

Receiver gain could be set too high or low. Lower or raise
gain to locate the line. See “Controls” on page 13.