800 watt inverter generator, Specifications – EarthQuake MC43ES User Manual

Page 11

Advertising
background image

Check for parts online at

www.getearthquake.com

or call 800-345-6007 M-F 8-5

11

Operator’s Manual

800 Watt Inverter Generator

Ac Voltage

60Hz -120V

Max Output

800 watts

Rated Output

700 watts

Dc Output

12V / 4.5A

Engine Displacement

40cc

Engine Type

4-cycle

Noise Level (@7M)

58 dB

Fuel Tank Capacity

0.55 gallons (2.1 liters)

Recommended Fuel Type

Minimum 87 octane gasoline

with NO ethanol content

NOTE: If using an ethanol

blended fuel, a fuel

stabilizer, mixed

to manufacturer

specifications, is

recommended.

Run Time (25% Load)

8.2 hours

Oil Tank Capacity

11.8 ounces (.35 liter)

Oil Type

10W-30 (SJ, SL or better)

Spark Plug

CMR6A (TORCH)

Spark Plug Gap

0.6 - 0.7 mm

Weight Of Unit

20 lb

Unit Size L X W X H

(Inches)

15.6 x 8.2 x 14.0

SPECIFICATIONS

Oil Warning System
When the oil level reaches a low level, the engine will stop

automatically. In order to restart the engine, the oil must be

refilled.

NOTE: It is important to check the oil level before each use.

Engine Switch
The engine switch must be in the RUN position to start

and run the generator. Push the engine switch to the STOP

position to stop the generator. SEE FIGURE 1

NOTE: It is recommended to keep the engine switch in the

STOP position while the generator is not in use.

Economy Control Switch
When the economy control switch is in the ON position, the

economy control unit controls the engine speed according to

the connected load. The results are better fuel usage and lower

noise levels. SEE FIGURE 1

NOTE: When starting the generator, and while plugging

in and starting connected devices, make sure the

economy control switch is in the OFF position.

When all units are running smoothly, push the

economy switch to the ON position .

DC Circuit Protector
The DC circuit protector turns off automatically when the load

exceeds the generator’s rated output. SEE FIGURE 1

NOTE: If generator turns off due to access load, reduce

the load to within specific generator rated output

levels.

Fuel Tank Cap Air Vent
The fuel tank cap is provided with an air vent knob to stop fuel

flow. The air vent knob must be turned clockwise to the OPEN

position to run the generator. This will allow for fuel flow in

the engine. When the generator is not in use, turn the air vent

knob counterclockwise to the CLOSED position. This will block

air flow to the fuel tank. SEE FIGURE 2
Fuel Valve
The fuel valve must be in the ON position to run the generator.

When the generator is not in use, turn the fuel valve to the

OFF position. SEE FIGURE 2

FIGURE 1

DC PROTECTOR

ONPUSH

OFF

ENG. SW.

ECON.

POR

TA

-0003R1

ON

OFF

RUN

STOP

CL

OS

E

O

PE

N

CLOSE

OPEN

ON

OFF

POR

TA

-0003R1

FIGURE 2

Advertising
This manual is related to the following products: