Operator’s Manual

800 Watt Inverter Generator

14

Check for parts online at

www.getearthquake.com

or call 800-345-6007 M-F 8-5

USING ELECTRICAL POWER

AC Application:

1. Turn off the switch(es) of the electrical device(s) before

connecting to the generator.

2. Insert the plug(s) of the electrical device(s) into the

receptacle.

3. Start electrical device(s). Let run for a few moments

and then push the economy control switch to the ON

position.

Overload Indicator Light:
The overload indicator light comes on when an overload of

a connected electrical device is detected, the inverter unit

overheats or the AC output voltage rises. The electronic

breaker will then activate, stopping power to the generator

in order to protect the generator and any connected electric

devices. The output light (green) will flicker and the overload

indicator light (red) will turn on, then the engine will stop

running. If so please follow the following steps:

1. Turn off any connected electric devices.
2. Reduce the total wattage of connected electric devices to

be within the generators range.

3. If total wattage is within range, check for blockages in

the cooling air inlet and around the control unit. If any

blockages are found, remove.

NOTE: The AC output of the generator automatically

resets when the engine is stopped and then

restarted.

4. Restart engine. Make sure to follow starting instructions.

DC Application (Option):
This usage is applicable to 12V battery charging only. Make

sure that the economy control switch is in the off position while

charging the battery.

1. Connect the battery charging cable to DC receptacle on

the generator.

NOTE: A battery charging cable is included in the box.

2. Connect to the battery terminals using the charging

leads. Make sure the red lead is going to the positive (+)

post of the battery and the black lead is going to the

negative (-) post of the battery.

3. Once the connection is confirmed make sure the DC

circuit protector is in the ON position.

WARNING

DO NOT USE WORN, BARE, FRAYED OR OTHERWISE

DAMAGED ELECTRICAL CORD SETS WITH THE

GENERATOR. DO NOT HANDLE ANY KIND OF

ELECTRICAL DEVICE WHILE STANDING IN WATER,

WHILE BAREFOOT OR WHILE HANDS OR FEET ARE

WET.

CAUTION

BE SURE THE ELECTRICAL DEVICE(S) IS(ARE)

TURNED OFF BEFORE PLUGGING IN.

BE SURE THAT THE TOTAL LOAD IS WITHIN

GENERATOR RATED OUTPUT.

BE SURE THE SOCKET LOAD CURRENT IS

WITHIN THE SOCKET RATED CURRENT.

THE ECONOMY CONTROL SWITCH MUST BE

TURNED TO THE OFF POSITION WHEN USING

ELECTRIC DEVICES THAT REQUIRE A LARGE

STARTING CURRENT.

THE AC OUTPUT OF THE GENERATOR

AUTOMATICALLY RESETS WHEN THE ENGINE

IS STOPPED AND THEN RESTARTED.

THE OVERLOAD INDICATOR LIGHT MAY COME

ON FOR A FEW SECONDS AT FIRST WHEN

USING ELECTRIC DEVICES THAT REQUIRE A

LARGE STARTING CURRENT.

BE SURE THE ECONOMY CONTROL SWITCH

IS IN THE OFF POSITION WHILE CHARGING

BATTERIES WITH THE DC APPLICATION.