Operator’s Manual

800 Watt Inverter Generator

NOTE: If the engine does not start prime again and repeat.

7. Allow the engine to warm up.
8. Move choke lever back to RUN position. SEE FIGURE 6
9. Allow for the engine to run without a load for a few

minutes.

NOTE: For cold weather operation, store the unit in a cool

environment. Transferring the unit from a cold to

a warm place can cause the build up of harmful

condensation.

To Stop The Generator

1. Disconnect any electrical devices.
2. Put the engine switch in the STOP position. SEE FIGURE

5

3. Turn the fuel valve to the OFF position. SEE FIGURE 4
4. Turn the fuel tank cap air vent counterclockwise to the

CLOSED position. SEE FIGURE 4

WARNING

MAKE SURE THE UNIT IS IN A STABLE POSITION

BEFORE PULLING THE STARTER HANDLE.

FIGURE 6

FIGURE 5

CAUTION

IF ENGINE FAILS TO START AFTER FOLLOWING

STARTING PROCEDURES, PLEASE CONTACT

OUR CUSTOMER SERVICE DEPARTMENT AT

800-345-6007.

STARTER ROPE CAN CAUSE AN

UNANTICIPATED JERK TOWARDS ENGINE.

PLEASE FOLLOW INSTRUCTIONS TO AVOID

INJURY.

NEVER LEAVE ENGINE RUNNING WHILE

UNATTENDED. TURN OFF AFTER EVERY USE.

NEVER CARRY GENERATOR FROM ONE

LOCATION TO ANOTHER WHILE ENGINE IS

RUNNING.

ALWAYS WEAR A PROTECTIVE HEARING

DEVICE.

DO NOT START ENGINE IF FUEL IS SPILLED.

WIPE OFF EXCESS FUEL AND ALLOW TO DRY.

STARTING THE GENERATOR WITH ELECTRICAL

DEVICES CONNECTED COULD DAMAGE THE

GENERATOR AND THE CONNECTED DEVICES.

DC PROTECTOR

ONPUSH

OFF

ENG. SW.

ECON.

POR

TA

-0003R1

ON

OFF

RUN

STOP

CL

OS

E

O

PE

N

CLOSE

OPEN

ON

OFF

POR

TA

-0003R1

FIGURE 4

RUN

CHOKE

PRIMER BULB

POR

TA

-0006R1

OPERATION

Starting Generator
Before starting make sure nothing is connected to the

generator and it is in a stable position. The economy control

switch should be in the OFF position until the generator and

the later connected devices are running smoothly.

1. Turn the fuel tank cap air vent to the OPEN position. SEE

FIGURE 4

2. Turn the fuel valve to the ON position. SEE FIGURE 4
3. Push engine switch to the RUN position. SEE FIGURE 5
4. Press the primer bulb six times with the choke in the RUN

position. SEE FIGURE 6

NOTE: Priming the engine should only be necessary for

cold starts and after refueling.

5. Move choke lever to the CHOKE position. SEE FIGURE 6

NOTE: The choke is not necessary if the engine is warm.

6. Use one hand to securely hold the carrying handle of the

generator. With the other hand pull the starter handle

slowly until resistance is felt (this is the “compression”

point). Return the handle to its original position and then

pull swiftly. Do not fully extend the rope. After starting,

slowly return the starter handle to its original position.