Message Description

Port #n: Listening for
connections on tcp port pppp
was not possible (Error #nn)

Port #n: Connection attempt
to ###.###.###.###:##### was
not possible (Error #nn)

Port #n: Incoming connection
on tcp port <Port Number>
from ###.###.###.###:#####
(Error #nn)"

This message indicates that a TCP
connection was not possible due to error
nn

. Errors are listed below:

1 - the i/o request has been scheduled but
not completed
2 - no more i/o paths are available
3 - requested operation was not supported

by the driver
4 - the provided i/o buffer was not valid
5 - requested operation cannot be done in

current state
6 - too many connections of this type are

already open
7 - socket connection type ("domain") is

unknown
8 - socket protocol type is unknown
9 - socket has already been bound to
another port
10 - requested port number is already is

use
11 - requested address was not valid for

operation
12 - operation requires bound port but

socket is unbound
13 - device is not ready for the requested

operation
14 - cannot open connection because

socket is already connected
15 - operation requires connected socket

but not connected
16 - data message is too big for transport

type (usually udp)
17 - requested operation would block this

thread -- try later
18 - incoming data corruption has been

detected
19 - no data is available for this operation
20 - no route available from this host to

destination host
21 - storage device can accept no more

data (eg. disk full)
22 - requested option is not available

7-8