VF / DSL Cable Qualifier

170

MAIN
MENU

E

F

CHG

VIEW

DETAIL

SAVE /

UPLOAD

DMM:
Load Coil

Length
Longitudinal Balance
Balance at 1 Khz
Capacitive Imbalance

SHDSL Data Rate
Disturbed ID

Passed

3 found Failed
2999 f t

Skipped

N/A

Skipped
Undetermined

Failed

Cable length: 2999 ft. dBRL = 40.5+ Load coil or splitter detected

F

IGURE

8.11.4B

-

R

ESULTS OF THE

SHDSL

A

UTO

T

EST

-

FAIL

The functions buttons at the bottom of the screen are as follows:

VIEW DETAIL

Allows a user to view the results of each test making up a completed SHDSL Auto
test. The SHDSL Auto test will not do a Single-End SHDSL test if a Load Coil is
detected.


Pressing the SAVE / UPLOAD button shows a pop-up window where the user is allowed to upload results,
and save results to internal memory or to external USB memory.

UPLOAD
RESULT

Choosing UPLOAD RESULT from the SAVE / UPLOAD pop-up menu sends the result
that appears on the CableSHARK screen (current test or recalled test) to a PC via a
NULL modem cable. The remote control program Visi-SHARK can be used to capture
and analyze the results on a PC.

SAVE TO MEM

Choosing SAVE TO MEM from the SAVE / UPLOAD pop-up menu invokes the SAVE
SESSION menu. From here, the test results can be saved to internal non-volatile
memory. See Section 5.3 for more information.

SAVE TO USB

Choosing SAVE TO USB from the SAVE / UPLOAD pop-up menu invokes the SAVE
SESSION menu. From here, the test results can be saved to external USB memory.
See Section 5.3 for more information.