If the line card is not connected or is not detectable by the CableSHARK, the Ground Resistance test
displays the following screen.

MAIN
MENU

E

F

CHG

SAVE /

UPLOAD

Line card = not detected

TEST
SETUP

F

IGURE

13.2.4B

L

INE

C

ARD

N

OT

D

ETECTED



The Ground Resistance measurement is executed in the following fashion.

1. Measure the open loop (on hook) tip-ring voltage (Station voltage). The voltage must be negative. If

not an error message reporting “Tip & Ring polarity reversed” will be displayed.


2. The CableSHARK will detect the balanced-unbalanced source (on hook) by measuring the ring-

ground voltage. For a grounded system it must be ≤5 V. If the ring-ground voltage is ≥5 V, the line
is balanced.

3. The CableSHARK measures the loop current (off hook) by seizing the line with a 435 ohm internal

load

4. For the constant voltage sources, the CableSHARK measures the tip-ring voltage (off hook) with

the 435 ohm load.