Cleaning vfl-type connectors, Arning – EXFO MaxTester Series User Manual

Page 133

Advertising
background image

Maintenance

MaxTester Series

123

Cleaning VFL-Type Connectors

Cleaning VFL-Type Connectors

VFL-type connectors are fixed on your unit and can be cleaned using a
mechanical cleaner.

To clean a connector using a mechanical cleaner:
1.
Insert the mechanical into the optical adapter, and push the outer shell

into the cleaner.

Note: The cleaner makes a clicking sound to indicate that the cleaning is done.

2. Verify connector surface with a portable fiber-optic microscope (for

example, EXFO’s FOMS) or fiber inspection probe (for
example, EXFO’s FIP).

W

ARNING

Verifying the surface of the connector with a fiber-optic microscope
WHILE THE UNIT IS ACTIVE WILL result in permanent eye damage.

Advertising