45. Locate the limit switch trigger on the upper right inside of the tower side. Place a mark on the tower

side aligned with one of the flat head adjustment screws on the limit trigger (

FIG. 4.16

).

46. Measures down from the mark on the tower side by the same dimension recorded in the previous

step and mark the tower at this point.

47. Loosen the two flat head adjustment screws in the limit switch trigger until the trigger moves but do

not remove them completely. Slide the limit switch trigger assembly down until the same flat head
screw where the upper mark was made is now aligned with the lower mark on the tower side.
Tighten the two screws.

48. Run the VPL Platform up until it stops and the ENTER/EXIT indicator is illuminated.
49. Check the height alignment between the upper landing and the platform deck and fine tune by

adjusting limit switch trigger up or down as needed. Final height should be set so the platform height
is approxi

mately 1/4” above the landing height when the VPL is unoccupied.

50. Verify proper operation of guard ramp.
51. Double check to ensure the flat head screws on the limit switch trigger are securely tightened.
52. Replace the front tower panel followed by the power head cover.