Troubleshooting your dyson – DYSON DC07 User Manual

Page 18

Advertising
background image

Troubleshooting your Dyson

Problem

Potential solution

Less than normal or no pickup

• If vacuuming non-delicate carpeting, ensure brush control is

from cleanerhead or

set on carpets mode. Note: brushbar will only spin when the
handle is reclined.

Machine turns off in use

• Remove and check washable filter to see if it is clean (filter

should be blue in color). Wash filter if necessary as shown
on page 8.

• If you removed the soleplate, it must be refitted flush with the

cleanerhead. If it is not, refit soleplate as shown on page 15
and re-check performance.

• Be sure the filter housing, U-bend, and airway inspection valve

are snapped in securely and confirm there are no blockages.

Less than normal or no suction

• Confirm the U-bend is in place and that there are no blockages.

from wand or hose

• Remove the wand and check for blockages.

• Confirm the hose has no blockages or holes by stretching it out.

• Be sure the filter housing and airway inspection valve are

snapped in securely and confirm there are no blockages.

• Remove and check washable filter to see if it is clean (filter

should be blue in color). Wash filter if necessary as shown
on page 8.

Brushbar not spinning

• Ensure brush control is set on carpets mode.

Note: brushbar will only spin when the handle is reclined.

Loud ‘ratcheting’ noise coming

• Ratcheting may indicate there is an obstruction in the brushbar

from cleanerhead when

and is meant to protect the belt in the machine. Note: the

vacuuming

ratcheting may also occur if your carpet is not adequately
attached to the floor or if your rug has loose tassels. (This noise
does not hurt the machine.)

• Check to see if there is an obstruction in the brushbar as shown

on page 15.

• Note: when refitting the soleplate it must be fitted securely.

Affix as shown on page 15.

• If there is no obstruction, you may want to set brush control

to bare floors mode.

Unit will not stand upright

• Stand behind the vacuum holding the handle at a 45

degree angle.

• Locate and remove the airway inspection valve and take note

of the square plastic molding where the airway inspection valve
plugs into. (It should slide up and down.)

• Snap that square plastic piece up toward the ceiling.

• After it snaps into place, the unit will stand upright.

Refer to page 3 for an illustration of DC07. If this does not help with your problems, please call the
Dyson Helpline at 1-866-693-9766. The Helpline is open 7 days a week to answer your questions.

Dyson Helpline contact us at

1-866-693-9766

7 days a week

18

16852_DCO7_OP_MAN_US.qxd 5/7/07 14:00 Page 18

(Cyan plate)

(Yellow plate)

(Black plate)

(PANTONE Red 032 C plate)

10:39:28 2007-07-06 C_16852_DCO7_OP_MAN_US_4c1s.pdf