Charging / discharging lead-acid (pb) batteries, Discharging lead acid (pb) batteries notice, Charging lead acid (pb) batteries – HITEC X2-400: DC/DC Dual Port Charger User Manual

Page 21

Advertising
background image

19

Set the charge current on the left and the nominal voltage on
the right. Charge current can be set from 0.1-6.0A. The voltage
must match the battery being charged. Press the
START/ENTER key for more than 3 seconds to start charging.

The screen will display the real-time charging status. Press the
START/ENTER key to alter the charge current. Press the
START/ENTER key again to store the parameter settings you
set. Press the BATT TYPE/STOP key to end the program.

Discharging Lead Acid (Pb) Batteries

NOTICE

Due to the chemistry characteristic of a Pb battery, the cut-off point may be difficult to
detect at times. We recommend you use the CAPACITY CUT-OFF feature to protect the
battery. Refer to the Default User Preferences Setup section of this manual to set up
this feature.

Charging Lead Acid (Pb) Batteries

Set up the discharge current on the left and the nominal
voltage on the right. The discharge current can be set from
0.1-5.0A. The voltage should match the battery being
charged. Press the START/ENTER key for more than 3
seconds to start discharging.

The screen displays the real-time discharging status. Press
the Start/Enter key to alter the discharge current. Press the
Start/Enter key again to store the parameter value you set.
Press the BATT TYPE/STOP key to end the program.

CHARGING / DISCHARGING LEAD-ACID (PB) BATTERIES

DEC INC

DEC INC

‘>3 seconds’

Batt Type

Stop

Start

Enter

DEC INC

DEC INC

‘>3 seconds’

Batt Type

Stop

Start

Enter

Battery

Type

Elapsed

Time

Battery

Voltage

Charged
Capacity

Charge
Current

Battery

Type

Elapsed

Time

Battery

Voltage

Discharged

Capacity

Discharge

Current