2 lake processing and control, 3 modules and frames, 28 signal flow and lake® processing – Lab.gruppen PLM 20000Q User Manual

Page 34: 1 overview

Advertising
background image

28

Signal Flow and Lake® Processing

PLM Series Operation Manual rev 1.2.3

been rectified or the incorrect setting has been readjusted. Sensing circuits also transmit local output power
stage temperature, processor card temperature, and PSU temperature to the appropriate protection circuits.
Please refer to section 5.3 on page 18 further details.

Table 6-1 lists PLM Series analog input sensitivity in dBu and Vrms for various Amp Gain settings and
maximum/minimum ISVPL settings, assuming an analog input headroom of 26 dBu.

INPUT SENSITIVITY

ISVPL SETTING

194 V

193 V

153 V

17.8 V

GAIN (dB)

dBu

Vrms

dBu

Vrms

dBu

Vrms

dBu

Vrms

+44

+1.0

0.87

+0.9

0.86

-1.1

0.68

-19.8

0,08

+41

+4.0

1.22

+3.9

1.22

+1.9

0.96

-16.8

0.11

+38

+7.0

1.73

+6.9

1.72

+4.9

1.36

-13.8

0.16

+35

+10.0

2.44

+9.9

2.43

+7.9

1.92

-10.8

0.22

+32

+13.0

3.45

+12.9

3.43

+10.9

2.71

-7.8

0.32

+29

+16.0

4.87

+15.9

4.84

+13.9

3.84

-4.8

0.45

+26

+19.0

6.88

+18.9

6.84

+16.9

5.42

-1.8

0.63

+22

+23.0

10.90

+22.9

10.84

+20.9

8.59

+2.2

1.00

Table 6-1: Analog Input Sensitivity in dBu and Vrms

6.2 Lake Processing and Control

As outlined in section 2.2.3, this device integrates seamlessly into the Lake Processing environment,
providing all features, functionality and connectivity associated with all Lake Processors. The internal Lake
Processing includes programmable crossovers, EQ, dynamics and other functions, and can be fully con-
trolled via the supplied Lake Controller software. Additionally, many functions can be controlled or accessed
directly via the front panel.

The Lake Controller Operation Manual and Lake Network Configuration Guide are supplied on the accompa-
nying CD-ROM and additional documentation is available from the Start Menu after software installation.

6.3 Modules and Frames

6.3.1 Overview

A Frame represents one physical Lake Processor (e.g. a PLM or LM 26). A maximum of two Modules are
contained within each Frame; these are referred to as Module A and Module B. The number of Modules
shown in a given Frame is dependent upon the signal processing configuration of that Frame.

Each Module can be configured as a Classic Crossover (Bessel, Butterworth, Linkwitz-Riley), as a Linear
Phase Crossover, or as multiple full bandwidth Auxiliary Outputs. The default configuration for the PLM is
2 x 2-Auxiliary Output Modules, providing a total of four module outputs.

Advertising
This manual is related to the following products: