Back Panel Interface

71

PLM Series Operation Manual rev 1.2.3

Tests indicate that up to 20 PLMs may be have

their AES3 inputs daisy-chained together, however

circumstances and cabling used may reduce this

figure. Please refer to section 10.6.

8.4 RJ45 etherCON Network Connections

Two RJ45 etherCON style network connections are provided as shown in Figure 8-16.

SWITCHED 100/1000 Base-T

LINK

PRIM

ACT

SEC LINK

ACT

Figure 8-16: etherCON Network Connectors

The network connections auto-sense whether standard or crossover Cat-5e cables are in use. Pre-made
cables with moulded RJ45 plugs are recommended. If it is necessary to make up custom Cat-5e network
cables, use pinout described in Table 8-4.

Pin No.

Color

1

Brown

2

Brown + White

3

Green

4

Blue + White

5

Blue

6

Green + White

7

Orange

8

Orange + White

Table 8-4: RJ45 Wiring & Pin Out Description

Figure 8-17: RJ45 Wiring and Pin Out Diagram