Appendix, 1 faults and warnings overview, Appendix 73 – Lab.gruppen PLM 20000Q User Manual

Page 79

Advertising
background image

Appendix

73

PLM Series Operation Manual rev 1.2.3

9. Appendix

9.1 Faults and Warnings Overview

Fault or warning conditions are indicated by the LED shown in Figure 7-3 on page 34, and also by LEDs associ-
ated with the inputs and outputs on the PLM. As the LEDs indicate several types of faults or warnings, a
brief textual description of the fault or warning is provided on the LCD display. Section 7.8.2 on page 34 details
the fault and warning indications that appear on the front panel. Table 9-1 lists the events that may have
triggered each fault or warning condition.

Model

Displayed Text

Event Log Text

Category Description

ALL

AMP CH. MUTE

Amp Channel Mute

Mute

The audio signal has been muted in the
power output stage.

ALL

ANALOG IN
FAULT

Frame Fault: Analog Input

Fault

The analog input signal is corrupt due
to DC on the analog input, or there is an
issue with the internal A/D converter.

20000Q ATL ACTIVE

N/A

Warning

The output power is limited due to high
amplifier channel temperature - the amp
channel temperature limiter is active.

ALL

AUDIO FAULT

Frame Fault: Audio Interface

Fault

An internal audio fault has arisen and the
unit needs servicing.

20000Q BEL ACTIVE

N/A

Warning

Breaker Emulation Limiter present as the
nominal current reached. Improve the
power distribution and adjust the BEL
settings.

ALL

CAL ACTIVE

n/a

Fault

Ensures that the PLM’s power output
stages are not overloaded. This should
never happen during normal program
material.

20000Q CHECK AC

MAINS

Frame fault: Check AC Mains

Fault

The PSU received unstable mains, check
the mains configuration.

ALL

CLOCK SLIPPING

AES Clock slipping

Warning

The AES or Dante clock is slipping; verify
clock selection / generator. This will
cause high THD on signal, and if Dante
is running will result in an unstable signal
distribution.

ALL

CTRL OFFLINE

N/A

Warning

The PLM is no longer able to communi-
cate with the Lake Controller.

ALL

CURRENT CLIP

n/a

Clip

PLM’s power output stage current has
exceeded the fixed safe maximum and
the Current Peak Limiter has become
active to limit it.

ALL

INPUT CLIP

n/a

Clip

The input signal level is too high and is
causing clipping at the input stage

Advertising