Manual transmission with linelock, Page 16 of 31, Toggle switch arms linelock and 2-step ground – Lingenfelter L460145297 Lingenfelter LNC-2000 LS Timing Retard Launch Controller v2.0 User Manual

Page 17: Ground, 12v ground, Ctap-001, Lnc-2000, Linelock solenoid, Stov-002

Advertising
background image

Manual Transmission with Linelock

Newer vehicles with clutch pedal position (CPP) sensor.

A

B

C

LNC-2000

Red = MAP +5V
Black = MAP/Linear Ground
Purple = MAP/Linear Signal

F

= Linear Mode

.2 Volt = 0*
4.8 Volt = 15*

Max Retard

Toggle Switch

Arms Linelock

and 2-Step

Ground

85

86

30

87a

87

Ground

Linelock

Solenoid

+12V

Ground

Optional LED, On when
Arming Switch is ON and
Clutch Pedal is depressed.

Relay can be omitted if Linelock solenoid
has a lower current/amp draw than the
Momentary Switch rating.

Analog Output
0-3 volt, .2 volt per 1* of Retard
Connect to analog input of Data
Recorder.

Retard Activation Connect to Nitrous
WOT switch signal or to +12V relay
output from Nitrous controller.

Use this wiring configuration to simultaneously
activate the 2-step feature and linelock using
the CTAP-001 Clutch Switch and the STOV-002
MPH activated switch. The STOV-002 should be
set so that after the vehicle launches from the
line, the linelock and the 2-step are disabled.

+12V

Ground

Power - Status

CTAP-001

Clutch/Throttle Activation

Ground - Black

Output Normally On - Gray

Output Normally Off - Yellow

Position Switch

Percent x10

Percent x1

+12V Switched Power - Red

Activation Percentage

Analog Signal In - Purple

+12V Output, Norm Off - Orange

Hysteresis

0 .5

1

1.

5

2

2.5

3

3.

5

4

4.5

LPE CTAP-001 receives the
0-5V clutch position signal and
outputs a switched 12V signal.

To clutch pedal
position sensor

TVS

diode

When the LNC-2000 is powered up with no
MAP Sensor installed it will default to
Time Based Retard mode.

0

1

3

5

6

7

2

4

8 9

A

B

C

D

E

F

0

1

3

5

6

7

2

4

8

9

A

B

C

D

E

F

Power

STOV-002

Speed to Voltage

Ground - Black

Stage Out / Norm On - Gray

Activation Out / Norm Off - Green

PPM Signal Input - White

Co

Conv

nveerrtor

tor

Function Selection

Range Selection

+12V Switched Power - Red

Voltage Out - Yellow

85

86

30

87a

87

Ground

+12V

+12V

The STOV-002 is used to eliminate
the possibility of the linelock being
inadvertently re-engaged while the
vehicle travels down the track. The
STOV-002 should be set to a vehicle
speed below the first shift point.

Page 16 of 31

Advertising