LNC-2000 Receiving 0-5V Timing Retard Input from a Davis

Technologies TMS-Drag-MAP Series Traction Control Module

(Without the MAP Adapter)

A

B

C

LNC-2000

Red = MAP +5V
Black = MAP/Linear Ground
Purple = MAP/Linear Signal

F

= Linear Mode

.2 Volt = 0*
4.8 Volt = 15*

Max Retard

-Set the LNC-2000 to Linear Mode (”F” on

Timing Rate setting)

-Set the traction control module for the

desired timing retard ramp.

-Set the Max Retard setting on the LNC-2000.

-While the traction control module will

create the timing retard ramp, the LNC-2000

will still control the maximum timing retard.

The female MAP adapter connector must

either be modified or replaced because it

is keyed. The black and green wires also

need to be flipped so that the black wire

is pin A and the green wire is Pin B. There

are two solutions:

- LPE sells a keyless connector to replace

the stock connector (PN: L480320000).

- Remove the terminals from the stock

connector, drill out the keys in the

connector, and then reinstall the

terminals into the connector.

The TMS-Drag-MAP

Series Traction Control

Modules are property of

Davis Technologies

Page 27 of 31

Advertising