Billet Trim Tab Installation

10 of 11

715 Center Street Grayslake IL 60030 P: 847.752.2700 E: [email protected] www.livorsi.com

REV B MAY 2015

TTK EL Models

Testing:

The hydraulic system will be full of air, the system is designed to self purge this air when the tabs
are raised and lowered.

Purging Air

Before testing the system ensure the pump is filled with oil to the MAX level line.

To purge, fully raise and fully lower the tabs 3X times.

Check the oil level and inspect all hydraulic components for leaks.

Repeat fully raising and fully lowering of the tabs until operation is smooth.

NOTE: While purging the oil will foam (inducing air), allow to sit for 24 hours, fill as needed.

Fill the pump with oil:

The pump reservoir has markers indicating the
maximum and minimum oil levels.

The operating temperature and the oil used will
determine the reaction speed of the tabs.

FASTER

SLOWER

MIN

MAX

Types of Oil

Reaction Time

ATF

20w20

10w30

Advertising
This manual is related to the following products: