Section 7 - calibration – Lumagen Radiance 2143/2123 User Manual

Page 32

Advertising
background image

Section 7 – Calibration

Copyright 2009-2014 Lumagen, Inc.

Radiance 2123 and 2143, Rev 041614

24

Section 7 - Calibration

Your theater system needs to be calibrated. To brighten the image in the show room, most display

manufacturers intentionally change the display calibration away from industry standards. Unfortunately most

displays do not have the controls necessary to undo these errors, and even many of those with calibration

controls are not mathematically correct, making proper calibration impossible without an external calibration

device such as the Radiance.
Correcting these intentional errors, and other unintentional errors, so the image appears, as the director

intended, is a primary function of the Radiance. The Radiance has a host of features dedicated to this task.
It is recommended that a professional calibrator be hired to perform the calibration. An experienced

professional calibrator has the necessary tools and experience to extract the best performance from your

theater. However, you can improve your picture without hiring a professional if you prefer. You will need to

learn how to use the Lumagen test patterns. Then you need to spend time learning how various calibration

controls interact and how they affect image quality, with the most important being proper adjustment of the

Black level in the display or projector menu.

To understand Radiance calibration, it is important to note that setup and calibration parameters are split

into “input memories” and “output configurations.” Input memories are for source specific setup and

calibration. Output configurations deal with display setup and calibration. These are covered elsewhere in

this manual.

It is recommended that the internal Lumagen test patterns be used to calibrate the output configuration.

This will assure that any variance between sources do not affect the calibration of the display.

The recommended Lumagen calibration sequence is discussed in TechTip 2 on the Lumagen support

“Manuals and TechTips” page at

http://www.lumagen.com/testindex.php?module=manuals

. Please check

out this and other TechTips for information on setup and calibration.
After you have completed changes, make sure to save your configuration as shown below:

MENU Save OK OK OK