Section 8 – Miscellaneous Commands

Copyright 2009-2014 Lumagen, Inc.

Radiance 2123 and 2143, Rev 041614

25

Section 8 – Miscellaneous Commands

System Settings

Menu Mode

The menu mode controls what settings can be changed in the menu. In Locked mode nothing can be

changed in User Mode, Service Mode (temporary) and Service Mode (permanent). The default setting is

User Mode, which allows access to all the basic controls. The Service Mode allows access to all controls

including the color gamut controls. The configuration can be locked to prevent unintended changes. When

locked, input selection functions normally, but setup parameters are fixed. The command is:

MENU Other Menu controlMenu Mode (Locked, User mode, Service mode

temporary, Service mode permanent)

Timeouts

In the “Normal” setting the menu and test patterns will timeout in approximately three minutes. The “Slow”

setting extends the timeout by x10. Test patterns also have a setting for “Never” timeout. The command is:

MENU 0 9 0 5 (Normal, Slow) Ok
or MENU Other Menu controlTimeouts (Normal, Slow, Never)

OSD Enable

On-Screen-Display (OSD) shown after each user command. Shows the selected input, input aspect ratio,

and zoom. The command is:

MENU Other Menu controlOSD enable (On, Off)

Input Reselect

When the currently active input is reselected the input will be reinitialized and the input number will be

displayed. The command is:

MENU Other Menu controlIn Reselect (On, Off)

Menu Placement

In the “Standard” placement the menu is in the center of the screen. Choose “Center open” to move the

menu so that the center of the screen is open for display calibration measurements. The command is:

MENU Other Menu controlOSD enable Menu placement (Standard, Center

open)

Input Menu

Displays a list of inputs you can select when the “Input” button is pressed on the remote. The command is:

MENU Other Menu controlMenu Options Input Menu (Off, On)

Initial Power State

When power is connected, the unit will turn “on” automatically, or go to “standby-mode”. The command is:

MENU Other OnOff Setup Auto On → (Standby, Turn On)

Initial Input State

Sets which input and input memory is selected when the unit is turned on, either after power has been

removed or the unit has been put into standby. The command is:

MENU Other OnOff Setup Input Select (After Power Removed, After Standby)