Lock the Configuration

The configuration can be locked to prevent unintended changes. When locked, the input
selection functions normally, but setup parameters are fixed. The command format is:

MENU

→ MISC → LOCK → (UNLOCKED, LOCKED) OK

The following command can be used to unlock the configuration memories if the on-screen menu
cannot be displayed. The command is:

MENU 0 9 1 5

Same as MENU

→ MISC → LOCK → UNLOCKED OK

Test Patterns

Warning:

Test patterns can cause screen burn-in if left on-screen for more then a few seconds.

Activate test pattern. The … and † arrows select the test pattern. The intensity is adjusted from
10 to 100 IRE, in 10 IRE steps, using the ‡ and ˆ arrows. The command format is:

MENU

→ MISC → TPAT → OK […, †, ˆ, ‡]

Menu Timeout

The MENU timeout can be changed. The command is:

MENU 0 9 0 5

Toggle menu timeout. Short (default) or long


Front Panel LED Function

The front panel LED is illuminated for a short time after a command and then turned off. This
behavior can be changed so the LED light stays on while the unit is on. The command is:

MENU 0 9 2 5

Toggle LED as "activity" (default) or "power."

Zoom Step

A smaller zoom step of about 5% can be selected instead of the normal step of about 15%. The
command is:

MENU 0 9 2 3

Toggle zoom-step between default and 5%.

Sidebar Pan

To help reduce screen burn-in with 4:3 sources on widescreen displays, the output can be slowly
moved left and right a fractional pixel step every few minutes. The command is:

MENU 0 9 8 7

Toggle Sidebar-pan for anti-burn. Default = off.