User manual and installer guide, Saving the configuration, Visionpro hdp – Lumagen VisionProHDP User Manual

Page 29: Other commands, Save, Save undo, Revert to factory settings, Restore configuration saved during calibration, Revert to defaults for current output resolution

Advertising
background image

VisionPro HDP

User Manual and Installer Guide

© 2004-2006 Lumagen®, Inc.

26

Rev 1.1

Other Commands

Freeze frame

MENU 0 9 0 0

Freeze picture (RS232 code = ‘z’). Any button exits

S/W Rev

MENU 0 9 0 3

Display software revision, save-count and serial-number

Video/Film flag

MENU 0 9 1 8

Display input type on screen as video (V) or film (F)

Input Reselect

MENU 0 9 1 9

Ignore reselection of same input

TV Black

MENU 0 9 3 6

TV decoder black

TV Contrast

MENU 0 9 3 7

TV decoder contrast

TV MV Black

MENU 0 9 3 8

TV decoder Macrovision black offset

TV MV Contrast

MENU 0 9 3 9

TV decoder Macrovision contrast offset

In 3,4 sync level

MENU 0 9 4 4

Adjust sync-sense level for input 3 or 4

Saving the Configuration

Save

Note: If a save command is not executed, any changes will be lost when

the unit is put into standby power mode, or if power is interrupted.

Permanently save the current configuration. Note that, once saved, the configuration is
retained even if the unit is disconnected from power. Configuration from previous save is
retained to allow one-level of save-undo. The command format is:

MENU

SAVE

SAVE

OK

OK

Save Undo

Revert to the configuration over-written by the last save. Repeating the save undo
command toggles between the last two saved configurations.

The command format is:

MENU

SAVE

UNDO

OK

OK

Revert To Factory Settings

Sets all parameters to factory defaults. A

SAVE

is required to make permanent.

MENU

0

9

9

9

or

MENU

SAVE

FCTRY

OK

Restore Configuration Saved during calibration

During calibration, the video technician can save the resulting Lumagen configuration to
a special hidden configuration memory. This command restores that configuration in the
event that the user inadvertently changes the configuration. A

SAVE

is required to make

the restore permanent.

MENU

SAVE

RESTORE

OK

Revert To Defaults For Current Output Resolution

Sets output parameters to defaults for the current output resolution. A

SAVE

is required to

make permanent.

MENU

0

9

9

8

or

MENU

SAVE

FCTRY

OK

Advertising