Rs-232 output, Calibration cal, Unld – LW Measurements BWS NTEP Weighing Platform Scale 500lb User Manual

Page 20: Load, Specifications

Advertising
background image

BW/BWS Series Indicator Technical Manual

- 17 -

Press

key to confirm and press

to select

sigr /dual 1

/dual 2

Press

key to confirm and press

to select

cal

Press

key to confirm


Calibration Cal

Press

key to enter calibration, display will show kg or lb. press

key to select the calibration unit kilograms or pounds, press

key ,display will be show

unld

Remove all the weight from the platform.

When indicator get stable, press

key to confirm.

Display will be show the last calibration weight. If want to change the

calibration weight value, press

and

keys to change the active

digits and press

key to increment the value.

When the calibration value is correct, press

key to confirm.

Display will be show

load

Place the calibration weight on the platform.

When indicator get stable, press

key to confirm.

Display will com to normal weighing mode

8. RS-232 OUTPUT

8.1. Specifications:

RS-232 output of weighing data
Code : ASCII
Data bits : 8 data bits
Parity :No Parity
Baud rate : 600bps to 9600bps selectable

Advertising