BW/BWS Series Indicator Technical Manual

- 19 -

Decimal point=0, header1=22H
Decimal point=1, header1=23H
Decimal point=2, header1=24H
Decimal point=3, header1=25H
Decimal point=4, header1=26H
Header2 follow weigh status, default value=20H
If in net mode (tare value not 0), header2=header2|01H
If gross weight

“-“, header2=header2|02H

If overload or gross weight

“-“, header2=header2|04H

If unstable, header2=header2|08H
If weighing unit=kg, header2=header2|10H
Header3 follow weighing unit
If weighing unit=g, header3=21H
If weighing unit=oz, header3=23H
Weight1~weight6: weighing data
Tare1~tare6: tare value
Terminator1: 0DH
Terminator2: 0AH

Con3:

Header

0

Header

1

Weight

1

Weight

2

Weight

3

Weight

4

Weight

5

Weight

6

Weight

7

Unit1

Unit2

Status

Termin

ator1

Termin

ator2

Header0=01H
Header1 follow weight

“+” or “-“

When weight

“+”, header1=”+”, when weight “-“, header=”-“

Weight1~weight7: weight data (include decimal point)
Unit1~unit2: weight unit
Status: when stable, status=0, when unstable, status=1
Terminator1: 0DH
Terminator2: 0AH