PRW serial bench scale user’s manual

FUNCTION MENU SETTINGS

FUNCTION SUB-FUNCTION

DESCRIPTION

DEFAULT
VALUE

F3 off

bL

Set the backlight to be on,
automatic or off,
EL on
EL Au
EL off

EL Au

bEEP

Set

the

beep

mode.(check

weighing mode 2, check weighing
mode3, no beep)

F4 Prt

Set the RS-232 , at first set RS-232 working mode
(press TARE key to change, press ZERO key to sure)
P Prt: print weighing ticket when the M+ key is
pressed,
P Cont: send weighing data continuously, connect to
PC ,
ASK: ask and answer mode (bi-direction mode), connect
to PC.
Command

“R”: send weighing data to PC

Command

“T”: do tare operate

Command

“Z”: do zero operate

P auto: auto M+ mode.
Sei re

:

also send continuously


Then set baud rate

After set working mode, display will show b xxx, this is
current baud rate, you select baud rate by TARE key ad
press ZERO to sure.

If you set printer (P PRT, P AUTO), then you can set print
out format.
Display will

shows “PR x”, set the date/time M+ format,

Then display show “LAB x”, set gross/acc M+ format,
you can see detail below.
These parameter only available in MODE1(normal
mode), see detail in section 12.
Then set printer type,
TY-TP: mini ticket printer
TY 711: A711 label printer
LP-50: LP-50 label printer

P Prt

Prog

Pin

Enter the programming and calibration menus
by entering the correct password. See the
section 12.