OPTI-UPS IS5000LR User Manual

Page 24

Advertising
background image

23

8. SPECIFICATIONS

8.1 IS-LT Long-Run Series (Tower) 1000VA~5000VA

General Features:

Smart backup time estimation for any kind of battery

Adjustable voltage sensitivity, voltage-transfer points, & charging voltage

Generator compatible

Automatic restart of load after INVERTER AND UPS shutdown

Smart AVR function (Two buck / boost modes)

Cold-start capable

Audible alarm

Hot-swappable batteries

Network manageable (SNMP optional)

Full function of LCD display (LED display optional)

Smart battery management

Intelligent double stages of charging control, Wet battery compatible

Thermal control cooling fan

Output

120V Models

230V Models

IS1100LT : 1100VA / 660W

IS2200LT : 2200VA / 1350W

IS3000LT : 3000VA / 1800W

Power Levels crated at

nominal inputs

N / A

IS5000LT : 5000VA / 3200W

Output Voltage

100V/110V/120V Selectable

220V/230V/240V Selectable

Voltage Waveform

Sine wave

Crest Factor

3 1 ; (4.5 1 optional)

Output Frequency

(Synchronized to Mains)

Auto Select for 50/60Hz

47Hz ~ 55Hz for 50Hz nominal; 56Hz ~ 65Hz for 60Hz nominal

Regulation (Nominal)

±5% typical of nominal voltage (optional at ±10% AVR for wide I/P up to ±35%)

Regulation

(Battery mode)

±3% of selected output voltage (adjustable with the remote set-up software)

Transfer time (Typical)

Blackout 4ms; Brownout 4ms; Battery mode to Normal mode 4ms typical

Over current protection Over load alarm level 100% ~ 120%, Over load shutdown level 120% ~ 190%

(Adjustable by using the remote set-up software)

Input