OPERATING PROGRAM

8. Program Stop

9. Program Complete

During the charging process, press STOP to stop the charging process.

When the charging process finishes, an audible sound will be heard.

NiMH
NiCd

RE-PEAK

CYCLE

Pb

Batt
Type

Operation
Program

Description

This charging mode is for charging LiPo/LiFe/LiIon battery in normal mode.

This program is for charging or discharging lithium battery which will not be
used for long time.

The charging capacity may be a bit smaller than normal charging but the
process time will be reduced.

This mode is for balancing the voltage of lithium-polymer battery cells while
charging.

The charger will charge NiMH and NiCd batteries using the charge current
set by the user.

In this program the charger detects the condition of the battery which is
connected to the output and automatically charges the battery.
Note: you should set up the upper limit of the charge current to avoid
damage by excessive feeding current. Some batteries of low
resistance and capacity can lead to higher current.

In re-peak charge mode, the charger can peak charge the battery once,
twice or three times in a row automatically. This is good for confirming the
battery is fully charged, and for checking how well the battery receives fast
charges.

1 to 5 cyclic and continuous process of charge>discharge or
discharge>charge is operable for battery refreshing and balancing to
stimulate the battery's activity.

LiPo
Lilon
LiFe

CHARGE

DISCHARGE

STORAGE

FAST CHG

BAL CHARGE

CHARGE

AUTO CHG

DISCHARGE

CHARGE

DISCHARGE

Charging Program

Depends on different battery type, the operation programs are different.

This mode is for discharging LiPo/LiFe/LiIon battery.

This mode is for discharging NiMH/NiCd battery.

This mode is for charging Pb battery.

This mode is for discharging Pb battery.

13 ·