Ighting, Fter, Roiler – Southbend Platinum Steakhouse Broiler User Manual

Page 13: Ilots, Hutdown of, Broiler controls and components

Advertising
background image

OWNER’S MANUAL 1190950 REV 2 (11/14)

PAGE 13

OF 22

S

TEAKHOUSE

B

ROILER

L

IGHTING

A

FTER

G

AS

H

AS

B

EEN

S

HUT

O

FF

When turning on the main gas supply to an appliance or a group of appliances, do the following:
1. Make sure that all the control valves and power switches of all the appliances are in the OFF position.
2. Turn on the main gas supply valve.
3. Light the standing pilots of each connected appliance.

L

IGHTING

B

ROILER

P

ILOTS

The pilots should burn continuously unless the broiler is to be completely shut down. The broiler cavity has two or three

pilots, one near each burner. If the pilots are extinguished, the pilot gas supply is NOT automatically interrupted. To light

the pilots, do the following:
1. Turn the control valves on the front of the broiler to OFF.
2. Turn on the gas supply to the broiler (if not already on).
3. Light the pilots.

S

HUTDOWN OF

B

ROILER

To place the broiler in a standby state (ready for use), turn the burner control valves to OFF. The pilots will remain lit.
To completely shut down the broiler for an extended period (or prior to disconnecting the gas supply), turn OFF the

manual shutoff valves of all gas supply connections. (This will extinguish all pilots.)

O

PERATION

Figure 5

Broiler Controls and Components

Removable

Grease Chute

Pilot Adjustment

Access Hole

Removable

Heavy-Duty

Broil Rack

Removable

Stainless Steel

Drip Pan

Removable

Grease Drawer

Variable High-Low-O ff

Independent Gas

Adjustment

Release Paddle

Nine-Position Rack

Adjustment Arm

Gas Regulator with

1" Rear Connection

Flue Vent Chamber

Keep the drip pans in place below the rack when broiling! Without them in place,

excessive air will be pulled past the burners, reducing temperature and cooking efficiency.

Advertising
This manual is related to the following products: