Djustment of, Ressure, Egulator – Southbend Platinum Steakhouse Broiler User Manual

Page 18

Advertising
background image

S

TEAKHOUSE

B

ROILER

OWNER’S MANUAL 1190950 REV 2 (11/14)

PAGE 18

OF 22

A

DJUSTMENT OF

G

AS

P

RESSURE

R

EGULATOR

The pressure regulator is located at the rear right lower corner of the broiler. The regulator is preset for 6” W.C. for natural

gas, or 10” W.C. for propane gas. If adjustment is necessary, do the following:
1. Turn the broiler control knobs to OFF.
2 Attach a pressure-measuring device to the 1/8” NPT connector located on the main manifold (accessible by removing t

he grease drawer).
3. Turn the broiler control knobs to HIGH. With the burners lit, check the manifold pressure. The pressure should be 6”

W.C. (for natural gas) or 10” W.C. (for propane gas).
4. If necessary, adjust the pressure by unscrewing the top of the pressure regulator (use a screwdriver) to expose the

adjustment screw underneath. Rotating the adjustment screw clockwise increases the manifold pressure.
5. After the pressure has been adjusted, turn the broiler control knobs to OFF, and replace the top cap of the pressure

regulator. Disconnect the pressure-measuring device and replace the plug into the manifold.

T

ROUBLESHOOTING

Advertising