INSTALLATION AND OPERATION MANUAL, PAN STEAMERS, MODELS EZ24-3, EZ24-5

MANUAL 1195731 rev0 (11/22/2011) 19 HEAVY DUTY STEAM

8.0 TROUBLESHOOTING

GENERAL

PROBLEM

PROBABLE CAUSE

REMEDY

1. C

OOKING INDICATOR

LIGHT FAILS TO LIGHT
WITH

T

IMER SET

.

a. Main power circuit breaker

tripped.

Locate external circuit breaker for incoming

power and place in ON position.

b. Door interlock switch contacts not

closed.

Shut cooker door to close switch contacts.

Check alignment of door with switch.

c. Door interlock switch faulty.

Replace switch.

d. Indicator light burned out.

Replace light.

e. Faulty timer contacts.

Replace timer.

f. Faulty wiring.

Inspect condition of wire and tightness of all

connections. Correct as needed.

g. Fuse blown.

Replace with same rated fuse.

2.

S

TEAM FAILS TO

GENERATE WITH
COOKING INDICATOR
LIGHT ON

.

a. Faulty wiring.

Inspect condition of wire and tightness of all

connections. Correct as needed.

3. S

TEAMS CONTINUOUSLY

WITHOUT THE COOKING
OR READY LIGHT ON

.

a. Faulty thermostatic switch.

Replace thermostat.

b. Power switch - continuous steam

setting is selected.

This is normal operation when “continuous

steam” is selected.

4. T

IMER DIAL NOT

TURNING

.

a. Faulty timer motor.

Replace timer.

b. Faulty wiring.

Inspect condition of wire and tightness of all

connections. Correct as needed.

5.

BUZZER FAILS TO SOUND
AT END OF TIMER
SETTING

.

a. Timer contacts faulty.

Replace timer.

b. Buzzer faulty.

Replace buzzer.

c. Faulty wiring.

Inspect condition of wire and tightness of all

connections. Correct as needed.

Advertising