Southbend EZ24-5 User Manual

Page 20

Advertising
background image

INSTALLATION AND OPERATION MANUAL, PAN STEAMERS, MODELS EZ24-3, EZ24-5

MANUAL 1195731 rev0 (11/22/2011) 20 HEAVY DUTY STEAM

8.0 TROUBLESHOOTING (Continued)

COMPONENT TESTING

60-MINUTE TIMER

Timer Contacts

Defective timer contacts will result in failure of cooker compartment to operate. When this

occurs, remove the side panel and proceed as follows:

1. Turn off power to the cooker at external circuit breaker.

2. Disconnect all three wires from timer terminals.

3. Connect an ohmmeter between terminals 1 and 3.

4. Rotate timer dial beyond the “0 - Minute” point (any setting) to obtain a reading of zero

ohms on the ohmmeter. If zero ohm reading cannot be obtained, timer contacts are

defective and the timer must be replaced.

5. Move ohmmeter leads to terminals 1 and 4.

6. Rotate timer dial to “0 - Minute” position. (An audible click indicates correct position). If

zero ohm reading cannot be obtained, the timer is defective and must be replaced.

7. Remove ohmmeter and replace all three leads on timer terminals.

Timer Motor

A defective timer motor will cause continuous operation in the TIME mode, with the timer dial

failing to return to the “0 - Minute” position.

To confirm timer motor condition, proceed as follows:

1. Carefully check motor wire leads and tighten loose connections.

WARNING: Use care while working with control panel. Terminals

carry 240 Volts.

2. Turn on power to the steamer.

Advertising