Step 5: Connect Electricity Supply

!

WARNING

ELECTRIC GROUNDING INSTRUCTIONS

This appliance, when installed, must be electrically grounded in accordance with local codes, or in the
absence of local codes, with the National Electrical Code, ANSI/NFPA 70 or the Canadian Electrical
Code, CSA C22.2

, as applicable.

Ovens are shipped wired for either single-phase or three-phase power according to the original factory
order. Wiring diagrams are located on the side of the control panel assembly, as well as in this manual
(beginning on page 30). Be sure that the input voltage and phase match the requirements shown on the
serial plate, which is located inside the lower front panel.

Conversion between single-phase and three-phase power can be performed in the field (see page 27).

The oven must be adequately grounded.

Use 167°F (75°C) wire for all supply lines.

The following drawing shows the locations of items referred to in the following procedure.

A

Hole

Contactor

Grounding Lug

Terminal Block

1. CHECK THAT THE POWER SUPPLY CIRCUIT BREAKER IS OPEN.

2. Locate and remove the four screws that secure the lower front panel (items “A” in the drawing above).

Lift up the panel and pull it forward to remove it, then set it aside.

3. To connect the supply wires, locate and remove the five screws (3 back, 2 front), that secure the right

side panel to the oven.