CONTROL PANEL ACCESS AND SHUT-OFF SWITCH

To access the control panel components, remove the screw at the top of the control panel and pull the top
of the control panel out (see drawing below). A wiring diagram for the oven is located on the side of the
control panel assembly. When the control panel is slid out, all power to the control panel is cut off by
a shut down switch that is located directly behind and below the control panel.
To re-energize the
controls for troubleshooting, pull the white plunger on the shut down switch forward.

Screw

Location of Wiring Diagram

BLOWER WHEEL REPLACEMENT

To replace the blower wheel, do the following:

1. Remove racks and rack guides.

2. Remove rear air baffle in front of blower wheel.

3. Loosen the two square heads on blower wheel hub.

4. Pull blower wheel from motor shaft. If blower wheel is difficult to pull off, use puller disk (available from

Southbend as part number 1179100).

WIRING DIAGRAMS

A wiring diagram is located on the side of the control panel assembly (as shown on page 30). Wiring
diagrams also appear on the following pages of this manual. Which wiring diagram is appropriate depends
on the voltage.

Index of Wiring Diagrams

Page Number

Description

31

208/240 Volt Models

32

380 Volt Models

33

480 Volt Models

34

415 Volt WYE Models

Accessing Control Panel Components