Array Menu

The Array Menu can only be selected if there are one or more active arrays. A summary list

of arrays is displayed. Each line in the list displays the array's number, LUN, RAID level, state,

utility running, size, and name (thus, providing a quick overview of the entire RAID configuration

without going to lower level menus). After choosing one of the arrays, select one of the options

listed below:

Array Status

Drive Status

Array Statistics

Abort Initialization

Verify Function

Expand Function

Add Spare

Delete Spare

Change LUN

Change Array Name

Trust Array

Array Status

The Array Status (Figure 10) displays the following information:

State - Online, Offline, Critical, or Fault-tolerant.

Serial number of the array - Each array is assigned a unique serial number.

Name - The name given to the array.

RAID - RAID type (0, 3, 4, 5, 50, Volume, or Mirrored). The term mirrored is used

for RAID 1, RAID 0/1, and RAID 10 arrays.

Number of drives in the array when fault-tolerant (For example, if a three drive

RAID 5 array was created and one drive is lost, the number will still show three

drives).

Number of spare drives dedicated to this array.

TID and LUN number - Target ID and LUN number presented to the host system.